- 6 - AL602ULADA
Terminal Identification Table:
AL600ADA Power Supply Board*
Terminal
Legend
Function/Description
L,G,N Connect120VACtotheseterminals:Ltohot,Ntoneutral.
-DC+ 24VDC@6.5ampinalarmnonpower-limitedoutput.
ACFAIL
NO,C,NC
Form“C”drycontactsusedtoinstantaneouslysignalthelossACtolocalannunciation
devices,withACpresentterminalsmarkedNOandCareopen,NCandCareclosed.
WhenlossofACoccursterminalsmarkedNOandCareclosed,NCandCareopen.
ACLOCAL
NC,NO,C
Form“C”drycontactsusedtoinstantaneouslysignalthelossACtolocalannunciationdevices,with
ACpresentterminalsmarkedNOandCareopen,NCandCareclosed.WhenlossofACoccurstermi-
nalsmarkedNOandCareclosed,NCandCareopen.
BATFAIL
NO,C,NC
Form“C”drycontactsusedtosignallowbatteryvoltageorlossofbatteryvoltage.Undernormal
conditionsterminalsmarkedNOandCareopen,NCandCareclosed.Duringatroubleconditionter-
minalsmarkedNOandCareclosed,andNCandCareopen(Fig. 2, pg. 7).
+BAT- Stand-bybatteryinput(leadsprovided)(Fig. 2, pg. 7).
*Power Board Parameter Specifications:
• ACFailconditionwillreportapproximately30secondsafterlossofAC.Todelayreportfor2.5to3hourscut
jumperACDELAYonthePowerSupplyBoard(ACtroubleoutputdelayoption).IfthismodeisselectedthePower
SupplyBoardmustberesetbyremovingallpowertoitfor30seconds.
• Lowbatteryconditionwillreportatapproximately21VDC.
• Batterypresencedetectionwillreportwithin180secondsafterbatteryremainsundetected(missingorremoved).
Arestoredbatterywillreportwithin30seconds.
LED Diagnostics:
AL600ADA - Power Supply Board
Red (DC) Green (AC) Power Supply Status
ON ON Normaloperatingcondition.
ON OFF LossofAC,Stand-bybatterysupplyingpower.
OFF ON NoDCoutput.
OFF OFF LossofAC.Dischargedornostand-bybattery.NoDCoutput.
AL800LGK9E - Logic Board
LED OFF ON BLINK (LONG)* BLINK (SHORT)**
ON Normal AlarmCondition TroubleCondition TroubleConditionMemory
ON Normal AlarmCondition TroubleCondition TroubleConditionMemory
OFF Normal AlarmCondition TroubleCondition TroubleConditionMemory
OFF Normal AlarmCondition TroubleCondition TroubleConditionMemory
Input1 Normal AlarmCondition TroubleCondition ---
Input2 Normal AlarmCondition TroubleCondition ---
Fault Normal AlarmCondition --- ---
* Indicatescurrenttroublecondition.Whentrouble(open,shortorground)occursonaspecificoutput,the
correspondingredoutputLED,[OUT1-OUT4]willblink.ThecorrespondinggreeninputLEDwill
blinkaswell.Looptroublewillreportwithin30seconds.
**Indicatestroubleconditionmemory.Whenatroubleconditionrestores,theunitsredoutputLED,[OUT1-OUT4]
willblinkwithashorteranddistinctlyadifferentduration.ThegreeninputLEDswillbeoff(normalcondition).
Toresetthememorydepresstheresetbutton(Fig. 2c, pg. 7).TheLED(s)willextinguish.
Note:Ifindicatingcircuitshavebeenrestored,memoryresetisnotrequiredfornormaloperationoftheunit.