- 2 - R2416ULseries
Overview:
These Altronix Rack Mount CCTV Power Supplies provide 24VAC or 28VAC distributed via sixteen (16) fuse or
PTC protected outputs for powering CCTV Cameras, heaters and other video accessories.
Sixteen (16) Output Rack Mount Configuration Reference Chart:
Altronix
Model Number
Output Voltage
(VAC)
Total Output Current
(Power)
Number of Outputs
PTC Protected Outputs
(Class 2 power-limited
for Dry locations).
(Class 3 for Wet
locations).
Fuse Protected
Class 1 Outputs
Individual Output
Current (max per output
not to exceed total
output current)
Fuse Ratings
Primary In-line
Fuse Ratings
115VAC 50/60Hz Input
Current
Agency
Listings
R2416UL
24VAC 7 amp
16 Yes 3.5 amp
3.5
amp
3.5 amp/
250V
2.9 amp
28VAC 6 amp
R2416ULCB
24VAC 7 amp
16 Yes 2.5 amp
3.5 amp/
250V
2.9 amp
28VAC 6 amp
R2416300UL
24VAC 12.5 amp
16 Yes 3.5 amp
3.5
amp
3 amp
28VAC 10 amp
R2416300ULCB
24VAC 12.5 amp
16 Yes 2.5 amp 3 amp
28VAC 10 amp
R2416600UL*
24VAC 25 amp
16 Yes 3.5 amp
3.5
amp
6 amp
28VAC 20 amp
R2416600ULCB
24VAC 25 amp
16 Yes 2.5 amp 6 amp
28VAC 20 amp
*24VAC models: Outputs 1-8 provide 12.5 amp (300VA) max. Outputs 9-16 provide 12.5 amp (300VA) max.
*28VAC models: Outputs 1-8 provide 10 amp (280VA) max. Outputs 9-16 provide 10 amp (280VA) max.
Specifications:
Installation Instructions:
1. Mount unit in the desired rack location (Space unit at least 3” from any video monitors). Do not obstruct side air vents.
2. Set power disconnect circuit breaker to OFF position (Fig. 1d, pg. 3).
3. The unit is factory set for 24VAC operation.
For 28VAC operation, adjust unit prior to mounting and applying power as follows:
a. Open bottom of the unit by removing six (6) screws (Rack Mechanical Drawing & Dimensions, pg. 4).
b. For 28VAC operation, adjust unit prior to mounting and applying power as follows:
Change the wire position so that the black wire [28V] is connected to the terminal marked [P] and
the yellow wire [24V] is connected to the terminal marked [S].
c. After securing all wires for proper voltage place bottom panel back on the unit and fasten with the six (6) screws.
Note: R2416ULCB set for 28VAC operation is not Class 2 Rated, not power-limited.
Agency Listings:
• ULListedforCommercialCCTVEquipment(UL2044).
CULListed-CSAStandardC22.2No.1-98,Audio,
VideoandSimilarEquipment.
• CEEuropeanConformity
Output:
• 24VACor28VACoutputs(Factoryset@24VAC).
• Surgesuppression.
• Filteredandelectronicallyregulatedoutput.
• Shortcircuitandthermaloverloadprotection.
Visual Indicators:
• Sixteen(16)individualpowerLEDindicators.
• Illuminatedpowerdisconnectcircuitbreaker
with manual reset.
Features:
• Unitmaintainscamerasynchronization.
• Easeofinstallationsavestimeandeliminatescostlylabor.
•Removableterminalblockswithlockingscrewflanges.
Rack Dimensions (H x W x D):
• 2UrackmountchassisforuseinstandardEIA19”rack.
3.26” x 19.125” x 8.5” (83mm x 486mm x 216mm)